FOUNDATION
Over-Notched Floor Joists In Crawlspace
Support Columns Without Proper Footings
Buckling Foundation Wall From Hydraulic Pressure
“The Balancing Girder” Should Have Supports On Each End
“Shade-Tree Mechanic And Foundation Repair?” Automotive Jack Not Ok As Foundation Support
Deteriorated Beams And Moisture Damage
Girders Not Properly Supported
Cathedral Ceiling Without Rafter Ties Causes Top Of Wall To Bow Out
Inadequate Make-Shift Beams And Support Posts
Cracks With Displacement Due To Structural Movement
Failed Girder Due To Moisture Damage From Plumbing Leak
Efflorescence And Moisture Infiltration Through Foundation Wall
ROOF
Deteriorated Plumbing Vent Boots Will Allow Moisture Into The Attic And Ceilings
Improper Drip Edge Can Allow Moisture To Flow Back Into Soffits
Wall-Type Dryer Vent On Roof Will Leak, (And Prolong Drying Time)
Deteriorated Roof Penetrations On Up-Slope Side Not Visible From Ground at House in Homewood
Missing Shingle Causing Moisture Damage To Interior
Exposed Fasteners Are Prone To Leaking
Improperly Installed Vent Flashing Will Need Continual Repairs
Creative But Nonfunctional Flashing
Damaged Framing Under Roof Decking Creates Opening Into Attic
Flashing – Not Just A Lewd Act In Public – Actually Needed Between Roof And Wall
Ran Out Of License Plates - Had To Use Shingles For Rest Of Roof
Ridge Vent Improperly Installed With Exposed Keyholes Below
PLUMBING
Failure Prone Corrugated Drain Lines And Electrical Tape Used For Plumbing Repairs in Cahaba Heights Home
Broken Drain Line Held Together With Bungee Cords
Drain Without Trap Emits Toxic Sewer Gasses Into House
Waste Line Not Properly Vented Through Roof Causes Traps To Siphon Out
S-Trap Configuration Prone To Siphoning And Loosing Water Seal… Two S-Traps Together Are A Work of Art in Highland Park Home
Main Valve Leaking At Foundation Wall In Crawlspace
Leaking Waste Line Under House From Improper Junction
Duct Tape Used As Plumbing Repair For Leak Under Cabinet
Missing Clamp Causes Waste Line To Leak In Crawlspace in Birmingham Home
Crimped Supply Line Under Sink Prone To Failure in Hoover Home
Open Waste Line In Crawlspace Releases Hazardous Fumes
Putty Not “Mighty” Enough For Plumbing Repair
ELECTRICAL
Whole House Ground Severed In The Main Panel
Most Electrical Issues Affect Performance And Safety At The Same Time
Corrosion On Terminals Can Cause Overheating And Create A Fire Hazard
Multi-Tapping – Too Many Wires In A Single Terminal Can Prevent Positive Contact
Improper Splice In Subpanel at Home in Homewood
Exposed Wiring And Open Junction Boxes Pose A Shock Hazard
“Creative Wiring” Can Pose A Variety Of Safety Concerns
Exterior Outlet Not Properly Sealed Allows Moisture Into Box
Receptacles Should Be Inspected Before Problems Occur
Broken Receptacles Should Be Replaced
Faulty Wiring In Receptacle Is A Fire Hazard
Non-Exterior Rated Wire Looses Multiple Battles With Weed Eater
HVAC/MECHANICAL
Frozen A/C Refrigerant Line in Homewood Home
Condensate Line Without Coupling Installed With Electrical Tape And Leaking
Missing Insulation On A/C Line In Attic Creates Condensation And Damages Ceiling
Condensate Line Termination Location Could Cause Foundation Issues
Damaged Electrical Conduit Can Create A Shock Hazard Around Condensing Unit
Open Plenum Blowing Heated And Cooled Air Directly Into Crawlspace
Missing Insulation On Ducts In Attic Will Reduce Efficiency
Leaking And Corroded Supply Line Can Reduce The Service Life Of Water Heater
Shelving And Hanging Clothes Against Hot Vent Could Cause Fire in Birmingham Home
Evidence Of Improper Combustion Due To Rust In Burner Chamber in Avondale Home
Furnace Vent Pipe Lacks Proper Clearance From Combustibles And Wood Has Begun To Char
Disconnected Dryer Vent In Basement in East Lake Home
GROUNDS
Retaining Wall Cracking And Leaning Due To Pressure
Termite Damage To Fencing Can Spread To House
Cracks With Displacement Compromises Wall Strength
Steps Cut To Wrong Size With Unsafe Bearing On Risers
Failing Retaining Wall Causing Driveway Above It To Begin To Collapse
Missing Deck Flashing Causes Siding To Deteriorate And Fall
Unseated Bolts Causes Deck To Pull Away From Wall
Joists Loosing Attachment And Barring From Bowed Outer Rim Joist
Improper Ledger Board Causing Joist To Split From Pressure
Do You Think This Deck Contractor Offered A Warranty?
Deck Not Secured To Support Posts
2x4 Joists Are Inadequate For Deck Framing
EXTERIOR
Roof To Poorly Designed Addition Creates A Dam In The Window Seal And Will Continually Allow Rain Into Wall And Interior Of Home in Homewood
Termite Damage To Wood Behind Garage Door Trim
Chimney Sealed Off Rendering Fireplace Out Of Service
Deferred Maintenance Resulting In Advanced Weather Damage And Rotted Wood
Wood To Earth Contact At Crawlspace Access Creates An Invitation For Termites at Birmingham Home
Rotted Soffits From Poor Guttering
Trim On Townhouse Only Visible From Neighbors Yard Over Fence
Underside Of Chimney Not Sheathed Creates Opening Into Crawlspace
Windows Not Properly Flashed Or Sealed Resulting In Moisture Damage To Interior Wall of Home in Hoover
Damaged Trim On Back Of Chimney Not Visible From Ground
Debris Filled Gutters Can Deteriorate Soffits – But Makes A Nice Trellis in Mountain Brooke Home
Bicycle Helmet Used To “Winterize” Leaking Hose Faucet
INTERIOR
Moisture Damage To Flooring Covered By Rug At Entryway
“Flip That House Back.” Kitchen Remodel Placed Outlet In Unusable Place
Leaking Toilet Should Be Reseated With New Seal To Prevent Further Floor Damage
Mold In Closet From Plumbing Leak Can Have Adverse Health Affects
Tub Not Properly Supported At Perimeter Or Sealed To Enclosure Was Rocking Back And Forth
Bathroom Vent Should Terminate To Exterior To Avoid Mold In Attic
Stains On Ceiling From Faulty HVAC Condensate Drain
Asbestos Gas Vent Emitting Toxic Fumes In Attic Instead Of Exterior
Rotted Roof Decking From Leak Prevention Attempt From Inside Attic
Broken/Splitting Framing Due To Improper Supports
Subcontractors Attempt To Stay Hydrated In Hot Attic?
Extensive Fire Damage Compromises Roof Structure Behind Hidden Attic Access in Birmingham Home
Appliances
Dishwashers be secured, running through the cycles. Washer arms have free movement. Pumps be operational, & unit be draining efficiently. Drain line is checked for high-loop or air gap device.
Damaged Door Gasket Causes Charring On Door - Ovens are evaluated for performance including heating, operation and functioning of door gaskets.
Our digital leak inspection lets you know whether the microwave is emitting unsafe levels of radiation. This is a service that many inspectors do not offer, and it’s included free in every inspection.
HALL OF SHAME
Gas Vent Pipe In Attic By Furnace Could Cause Fire Or Explosion
“Shade-Tree Mechanic And Foundation Repair?” Automotive Jack Not For Use As Foundation Support
Shock hazard – Hot Wire Left In Yard From Removed Spa
Power Strip – Not Designed For Outdoor Lighting
Wait Till It Stops Raining To Change Light Bulb
“You Might Be A Redneck If…” Wood-Burning Stove Actually In Use
Outlet Without Proper Clearance From Pool, Not GFCI Protected, Missing Cover Plate And Not Supplied With Exterior-Rated Wire - Don’t Hang Your Arm Over The Edge Here!
Apparently The Lowest Bid Didn’t Include Required Railings
No Balusters At Top Of 15 Foot-High Landing Poses Risk Of Injury
Flashing – Not Just A Lewd Act In Public – It’s Actually Needed Between Roof And Wall
Broken Drain Line Held Together With Bungee Cords
Roof Of Poorly Designed Addition Creates A Dam In The Window Seal And Will Continually Allow Rain Into Wall And Interior Of Home